Contact Us
Company address: Floor 1, Building 6, Zhongguancun Digital Economy Industrial Park, Baoding, 777 Lixing Street, Baoding City
Office telephone:
Technical Department:
Sales Department:
Website:http://www.hbswdq.com
E-mail:swsc@hbswdq.com
ABB TVOC-2 Arc Protection System
Key words:
Classification:
- Description
-
TVOC-2, ABB's Arc protection system™, based on the well-known TVOC design. More reliability, flexibility and simplicity.
Arc protection system™The protection of personnel and equipment is increased, and the operation of equipment can be efficiently guaranteed. Solutions for arc fault prevention.
With more than 40 years of operating experience, Arc Protection Systems™It has become the industry standard in several key markets.
Typical applications include all low-voltage switchgear and high-voltage switchgear.Reliability
• Certified according to functional safety (SIL-2) standards
• Over 40 years of experience in operating Arc protection systems
• Pre-calibrated optical sensor
• Current sensors with Rutgsky technology for LV and MV applicationsFlexibility
• IP54 degree of protection, HMI can be installed on the cabinet door
• The communication module operates in the same way as the HMI. Can communicate with remote control station via Modbus RTU
• Expandable optical sensors more than 30
• Configure the system to isolate the individual breaker zones of the switchgear
• Add current sensing devices only when dual regulation is requiredSimple
• Man-Machine Menu
• Rail mounted or fixed to wall mounted
• Easy-to-expand switchgear for increased functionalitySystem Introduction
Short-circuit faults in low-and medium-voltage switchgear are often accompanied by arcs. An arc fault can cause considerable equipment damage and personnel injury unless it is detected quickly. In order to avoid serious damage to the equipment and personnel approaching the switchgear during the arc flash, it is essential to cut off the power to the system before the energy level rises to a dangerous level. Using the Arc protection system™, The system power-off time can be reduced to 30-50 milliseconds.
arc protection system™Quickly detect arc faults and trip circuit breakers.
By detecting the arc, it can be activated almost instantaneously. Due to this key functional advantage, it covers all other protections and delays, which is critical when reaction time needs to be measured in milliseconds.System function
arc monitor
The arc monitor is designed as a modular unit, designed to suit various types and sizes of medium and low voltage switches.
It is designed according to functional safety, is SIL according to iec61508 and iec62061 certification, and attaches great importance to product reliability. This corresponds to performance class d according to EN ISO 13849-1. The security functions are handled entirely by the hardware. In addition, the system, the trip log and the user interface are all formed by a microprocessor.Connection
All connections can be secured from the Arc system™Front-end access. The pluggable junction box allows wiring prior to installation of the TVOC-2 into the cabinet.
The solid-state trip contacts are IGBT type, which ensures fast and reliable tripping.man-machine interface
• Handle settings with keyboard and full-text display
• Save error log and trip information after power failure
• Error logs and trip logs include time/date stamp of real-time clock
• TVOC-2 can install two HMI (cabinet door and body)
• Includes a 3 m cable
COM module can use Modbus RTUCurrent sensor (optional)
The sensing unit (CSU-2) is optional. The CSU-2 continuously measures the current, up to 3 phases, and is neutral to ensure that the light is generated by the arc flash.
• The CSU-2 detects if the cable connected to the current sensor is cut or if the connection is correct. The device notifies the TVOC-2 of the loss of the current signal.
• Rogowski coil current sensor for use with CSU-2
• CSU-2 and current sensors connected via RJ45
• CSU-2 the green light signal at the top to confirm correct connection
• High accuracy measurement of ± 3% of the wide range of nominal current
• Open Loop Variants
• Wall or rail mounting
Product inquiry